DRS Pro Radar X5

The main menu of the PRORADAR Series products is as shown in the picture below. In the PRORADAR series with different operating modes, you can start the search by selecting the operating mode in the main menu.

3D GROUND SCAN: Simultaneous 3D Ground Search Modes with PC. 3D LIVE SCAN: Simultaneous 3D Live Graphics Modes with PC. MEMORY SCAN: Record function to memory and transfer mode to PC. RESISTIVITY: Ground-mounted resistivity measurement mode. DETECTOR: Surface magnetic metal detection mode. GENERAL SETTING: Device main menu general settings menu.

Move to the operating mode you want to select, press the arrow buttons on the wireless control, then press the OK button.

3D FLOOR SEARCH (3D GROUND SCAN)
In the 3D Ground Scan menu, you can search automatically or manually with the PC simultaneously. Before making an automatic or manual search, you must select the number of call related signals, the number of lines and the signal time interval in SCAN SETTING.

AUTO SCAN: Automatic 3D Ground Search Mode MANUAL SCAN: Manual 3D Ground Search Mode SCAN SETTING: Search Settings

SEARCH SETTINGS (SCAN SETTING)
You must make the pre-call settings in the SCAN SETTING menu in the 3D Ground Scan menu.

STEP TIME: Auto 3D Enter the signal interval for the ground search mode. STEP: In 3D Ground search mode, enter the number of signals for each line. LINE: In 3D Ground search mode, enter the number of lines you want to call. SENSOR: Your device has intelligent sensor recognition. Automatically detects the installed sensor and automatically adjusts the data output.

3D AUTOMATIC GROUND SEARCH (AUTO SCAN)
3D In ground search mode, it is the mode in which signals are automatically sent. You must have already set the signal time interval. When you select, the signal will automatically search for the time interval, number of signal step, and call line sequence values ​​and start the data transfer to the PC. To start the search, go to AUTO SCAN mode and press the OK button. The connection screen with the PC will be displayed and then you will be prompted to press the START button. Before each call, you must make connection settings with the PC and connect with the device.

Press the START Button on the wireless control.
If you press the START button, the Automatic data transfer screen will be displayed and the data transfer will start.
The data transfer will start automatically. When the number of signals you have reached (Step) the device will stop and ask you to press the START button again. You need to do this every time the signal count is full.

The following screen will display the data as a grid. When the data is filled in, the number of pulses and the number of pulses you have entered before, and the data is stopped when all the frames are filled with graphics. Then your program will automatically bring it to 3D.

Graphs will first appear in grid format.
When the data acquisition is finished, the software will automatically turn to 3D. You can review the image below.
When you stop receiving data, you can review the data in 3D.

3D MANUAL FLOOR SEARCH (MANUAL SCAN)
3D In ground search mode, it is the mode in which signals are sent manually. The device will transfer data as you press the START button. When you make a selection, you can manually search the signal step number and search line order values ​​and start the data transfer to the PC.
Press MANUAL SCAN mode to start the search. The connection screen with the PC will be displayed and then you will be prompted to press the START button. Before each call, you must make connection settings with the PC and connect with the device.

Press the START Button on the wireless control.
If you press the START button, the Automatic data transfer screen will be displayed and the data transfer will start.

Data transfer will start manually. You must press the START button for each signal transmission. When the number of signals you have reached (Step) the device will stop and ask you to press the START button again. You need to do this every time the signal count is full.

The following screen will display the data as a grid. When the data is filled in, the number of pulses and the number of pulses you have entered before, and the data is stopped when all the frames are filled with graphics. Then your program will automatically bring it to 3D.

Graphs will first appear in grid format.
When the data acquisition is finished, the software will automatically turn to 3D. You can review the image below.
When you stop receiving data, you can review the data in 3D.

3D LIVE GRAPHICS (3D LIVE SCAN)
In the 3D Live Scan menu, you can automatically search for Horizontal or Vertical sections simultaneously with the PC. You can start live graphics mode by selecting Horizontal (Vertical) or Vertical from the 3D Live Scan menu.

Select the Horizontal or Vertical search mode. Press the OK button on the mode to select.

After making the selection, the connection screen with the PC will be displayed and then you will be asked to press the START button. Before each call, you must make connection settings with the PC and connect with the device.

Press the START Button on the wireless control.
If you press the START button, the Automatic data transfer screen will be displayed and the data transfer will start.

In live search mode, the graphic will continue continuously. If you press and hold the Back key, the device will return to the main menu and the graphic transfer will stop.

MEMORY REGISTER MODE (MEMORY SCAN)
In the Memory Scan mode in the main menu of the device, you can store the received data in the device memory without the need for a PC. You can then import the received data into the PC program. To use this mode, select Memory Scan mode from the device main screen.

MEMORY SCAN: You can store 16 different data in memory. UPLOAD TO PC: You can transfer the data in the PC to the PC. ERASE MEMORY: You can delete the recorded data. FORMAT MEMORY: You can erase and reset all memory. SCAN SETTING: You can set the call settings.

  • SEARCH SETTINGS (SCAN SETTING)
  • You must make the pre-call settings in the SCAN SETTING menu in the Memory Scan menu.
  • STEP TIME: Auto 3D Enter the signal interval for the ground search mode. STEP: In 3D Ground search mode, enter the number of signals for each line. LINE: In 3D Ground search mode, enter the number of lines you want to call. SENSOR: Your device has intelligent sensor recognition. Automatically detects the installed sensor and automatically adjusts the data output.

MEMORY SCAN
If you select Memory Scan, the following screen will appear. On this screen you will be asked to select the memory you want to save. Point to the memory number you want to save and press the OK button. Select either Auto or MANUEL call in the memory number you have selected. The search screen will appear according to the operating mode you have selected and press the START button on the joystick to start recording data from the 16 memories. In the memory function, you must press the START button each time for each signal.

The stored data remains stored in the main memory of the device. There is an asterisk (*) in front of the full memory. You can review the image below.

TRANSFERING THE DATA IN THE MEMORY TO THE PC (UPLOAD TO PC)
To transfer the data you have stored in the PC to the PC, you have to make your PC Program call settings as described previously. After connecting the wireless data transfer (bluetooth) between the device and the PC, press the OK Button on the wireless controller in the UPLOAD TO PC option in the MEMORY SCAN menu. Move to the Memory number you want to transfer and press the OK button. The full memory is indicated by an asterisk (*).
When you select the memory number you want to transfer, the connection screen to the PC will be displayed. You must have already made the connection settings and connected with the device. After the connection screen will read the data in the memory and transfer to the PC.

When the transfer is complete, the screen asks whether the memory should be deleted. If you select YES, it will be deleted. If you select NO, the data will remain in the memory until you delete it.

underground imagign

DELETE DATA IN MEMORY (ERAE MEMORY)
To erase the data you have memorized, you must select the ERASE MEMORY mode in the MEMORY SCAN menu. Press the OK button on the ERASE MEMORY mode. The Memory menu will appear. The filled memory is marked with an asterisk (*). Point to the Memory number you want to delete and press the OK button.

A warning screen will appear asking you to delete the memory you selected. If you select YES, it will be deleted. If you select NO, the data will remain in the memory until you delete it.

DELETING ALL THE DATA IN THE MEMORY (FORMAT MEMORY)
To erase the data you have memorized, you must select the FORMAT MEMORY mode in the MEMORY SCAN menu. Press the OK button on the FORMAT MEMORY mode. The Memory menu will appear. The filled memory is marked with an asterisk (*). Point to the Memory number you want to delete and press the OK button.

A warning screen will appear asking you to delete the memory you selected. If you select YES, it will be deleted. If you select NO, the data will remain in the memory until you delete it.

RESOURCE MODE (RESISTIVITY)
In the Resistivity section in the main menu, press OK to perform the functions in the Resistivity menu. Resistivity menu is as follows.

START SCAN: Auto-tuning. Between 4 probes searches between 6 lines
SETTING: It is the menu to set resistor and sampling time.

MANUAL SCAN: Use the manual search menu to search for that line by selecting the desired line.

Before Starting Measurement;
Check that the battery is fully charged. Make sure that the area in which you want to search for the probe is ready according to the way you want to search. Make sure that the cable clamps are correctly and fully inserted.

Tools necessary for the study; rubber glove to protect against electric shock, hammer to ground probes, cable pliers to remove probes from the earth, screwdriver for fuse replacement, white towel to protect the panel from sunlight, meter to determine the position and length of the probes to each other. These tools will help you in your work

AUTO SEARCH MODE (AUTO SCAN)
Press OK on START SCAN option in the resistivity menu to perform automatic search. DO NOT TOUCH PROBES when search starts.

When the automatic search is started, A LINE (1 and 2 probe), B LINE (2nd and 3rd probe) respectively, C LINE (3rd and 4th probe) D LINE (4 and 1. Probe) LINE (1st and 3rd probe) ) LINE (4th and 2nd Probe) will search. The screen on the right will appear during a call. You will see the material in the searched area on the screen and you can review it on the detail page.

After the automatic search is finished, the detail page will be displayed. On the detail page, he writes which line he saw which material.
If the probes are not connected, NOT CON. (No connection).

Pressing the OK key on the line you want to review will direct you to the detail page on that line.